Published camera intrinsics and distortion coefficients

This readable reference transcribes the camera intrinsics stored in the INDUS-AD calibration tables. These are source-reported values; independent per-camera calibration accuracy has not been established.

Intrinsic parameters

Parameter Published value
width 1920.0
height 1080.0
focal_length_x 1018.4666137695312
focal_length_y 1018.491943359375
optical_center_x 961.8368530273438
optical_center_y 539.9344482421875
skew 0.0
rmse 0.006899999920278788

Distortion coefficients

The coefficient order below is exactly the published array order. The table does not establish a distortion-model convention or assign coefficient names.

[
  25.8650601396,
  12.657001442,
  -7.02086e-05,
  1.94319e-05,
  0.5069227052,
  26.2723717293,
  22.7056487856,
  3.1677229543
]

Camera coverage

The inspected source table contains the same intrinsic values for these cameras:

An earlier random sample of 10 additional recording tables at revision 24c2a4c8da16d3bd12814830b6a0ea90059807c4 contained the same values across 69,542 calibration rows. This is sampled evidence, not a full-corpus calibration audit.

Resolution and geometric use

The calibration declares 1920 x 1080. The inspected recording has 1280 x 720 camera media. For the current devkit workflow, the publisher confirmed pure 1920×1080-to-1280×720 resizing without cropping on 23 October 2026. The adapter requires the explicit intrinsic_image_transform: "resize" policy and scales focal lengths, principal point and skew while retaining dimensionless distortion coefficients. See published sensor acceptance. This is producer-supplied pipeline information, not independent per-camera accuracy validation; the coefficient order/model limitation above remains. The reported RMSE has no verified unit or evaluation procedure in this reference.

These values alone do not establish camera-to-ego, IMU-to-camera, or camera-to-LiDAR extrinsics.

Historical inspection and current source

The revision and hash above describe the historical inspection. The relative Parquet link opens the current table, including the later calibration overlay; its bytes differ from that earlier inspected source. Historical revision identifiers are retained as provenance and are not current download pins.